• Nuclear Medicine • Radiation Oncology • Emergency Preparedness |
• PET Imaging • Nuclear Cardiology • Medical Physics |
| Home | Products | Contest Central | Newsletters | JRT Calibrations | Contact JRT |
Centralite® CT Moving Laser System Configurations |
|
Centralite CT Moving Laser Systems can be configured with 1 or 3 moving laser actuators. In addition, each of these configurations can include the "PC" option that allows the moving laser system to be connected to the treatment planning system via the network. Centralite CT Single Moving
A Single Moving Laser System is made up of a single moving laser actuator that is mounted directly over the CT couch and two fixed lasers mounted to the walls or pedestals on either side of the couch. In this system, the moving laser line from the overhead actuator defines the X (sagittal) plane for the patient, and this line can be moved from side to side across the patient's body. The other two planes are formed using the fixed laser in the moving laser actuator and the two red diode cross lasers (03-2221) mounted on either side of the couch. The fixed lasers (one in the ceiling, and one on each wall) form the Y (axial) plane, and two lasers (one on each wall) form the Z (coronal) plane. Both the Y and the Z planes are fixed relative to the room. These laser lines can be moved to the correct position on the patient by moving the couch up and down (Z plane) or in and out (Y plane). 03-2231 Single Moving Laser System $20,350.00
03-2231PC Single Moving Laser System with embedded PC $23,425.00
|
Centralite CT Three Moving
The Three Moving Laser System is made up of three moving laser actuators, one mounted directly over the CT couch as in the single moving laser system, and two mounted to the walls or pedestals on either side of the couch. In this system, the moving laser line from the overhead actuator defines the X (sagittal) plane for the patient, and this line can be moved from side to side across the patient’s body. The Z (coronal) plane is formed with the two moving lasers in the moving laser actuators mounted on either side of the couch. These two laser lines move up and down together to move the Z line on the patient. The Y (axial) plane is defined by the three fixed lasers, one in each of the moving laser actuators. This plane is fixed in position relative to the room. Its laser line can be moved to the correct position on the patient by moving the couch in and out. 03-2236 Three Moving Laser System $35,450.00
03-2236PC Three Moving Laser System with embedded PC $38,425.00
Mounting Options 03-2238ML Pedestal Mounting Kit for Moving Laser $1,300.00 03-2239ML Angle Bracket Kit for Moving Laser $475.00 |