Mammographic
ACR
Accreditation Phantom
|
|
The Mammographic Accreditation Phantom has been the #1 phantom listed by the ACR since the start of the MQSA program in 1994. The phantom provides the physical standard baseline for assuring the quality of the images produced by your mammographic system.
|
|
|
| |
 |
Digital Stereotactic Breast Biopsy Accreditation Phantom
|
|
The Digital Stereotactic Breast Biopsy Accreditation Phantom permits fast, easy comparison of conventional and digital image quality in a single exposure. The objects are some of those found in the Mammographic Accreditation Phantom specified by the ACR, so it makes comparison of the two imaging systems easy.
|
|
|
| |
 |
Single-Exposure High Contrast Resolution Phantom
|
|
The Single-Exposure High Contrast Resolution Phantom performs quality control inspections of mammography system resolution with just one exposure. Easy-to-use, and cost-effective, it meets ACR guidelines and MQSA requirements.
|
|
|
| |
 |
Special High Contrast Resolution Phantom
|
|
The Special High Contrast Resolution Phantom incorporates a 17.5 micron thick gold-nickel alloy bar pattern. Each bar pattern is positioned at 90 degrees to allow assessment of resolution perpendicular and parallel to anode-cathode axis in just one exposure. The 016B high resolution target has 18 segments from 5 lp to 28 lp/mm. The target is equivalent to 25 microns of lead or 2.6 mm of aluminum at 20 keV.
|
|
|
| |
 |
Digital
Mammography Phantoms
|
|
Digital Mammography Phantoms are tissue equivalent test tools that include: Digital Step Wedge Phantom,
Full Field Phantom,
Small Field Phantom, and
High Contrast Phantom.
|
|
|
| |
 |
Full Field
Digital Phantom
|
|
The Full Field Digital Phantom is specifically designed for assessment of digital system resolution and verification of CCD stitching. This phantom provides a series of L-shaped line pair targets from 4 to 12 line pair per mm. These targets are contiguously positioned to cover an 18 cm x 24 cm area at midplane in a 1 cm thick tissue equivalent slab.
|
|
|
| |
 |
Mammography Quality Control Package
|
|
The Mammography Quality Control Package has the tools a technologist needs to implement a comprehensive quality control program and insure their department is producing the best possible images and diagnostic information.
|
|
|
| |
 |
Tissue-Equivalent Mammography Phantom
|
|
The Tissue-Equivalent Mammography Phantom is 4.5 cm thick, simulates a 50% glandular tissue composition and is designed to test the performance of a mammographic system by a quantitative evaluation of the system’s ability to image small structures similar to those found clinically.
|
|
|
| |
 |
Mammography Phototimer Consistency Testing Slabs
|
|
The Phototimer Consistency Testing Slabs are designed for precise assessment of AEC system performance in accordance with American College of Radiology and MQSA recommendations. BR-12 (47% glandular / 53% adipose) is most commonly used but other glandular equivalencies are available.
|
|
|
| |
 |
Contrast and Resolution Mammography Phantom
|
|
The Contrast and Resolution Mammography Phantom measures the contrast and dynamic range of the imaging system. It also measures the system resolution of the focal spot length and width on mammography units (with optional Resolution Test Pattern.)
|
|
|
| |
 |
Contrast Detail Phantom
|
|
The Mammography Contrast Detail Phantom is designed to provide a means of quantitatively testing and monitoring the total performance of an entire mammographic imaging chain. Its small size, as well as the number and distribution of holes simulating embedded objects, make this phantom particularly useful in evaluating digital spot mammography systems.
|
|
|
| |
 |
Contrast Detail Mammography Phantom
|
|
The Contrast Detail Mammography Phantom is specifically developed to determine if mammographic images are indicating objects with very low contrast and very small diameter. Designed for full-field analog and digital units.
|
|
|
| |
 |
“Rachel” Anthropomorphic
Breast Phantom
|
|
The “Rachel” Anthropomorphic Breast Phantom produces an image with the contrast range and details found on a clinical mammogram. This phantom may be used for evaluation of effects of changing mammographic imaging parameters such as machines, machine settings, film/screen combinations, and digital image processing.
|
|
|
| |
 |
Mammography Research Set
|
|
The Mammography Research Set includes tissue equivalent phantoms 4, 5 and 6 cm thick. Each phantom contains identical embedded details. The glandular content of each phantom is 50%, 30%, and 20% respectively. Also included are phototimer compensation plates enabling a range of thickness from 0.5 cm to 7 cm with a glandular content of 30%, 50% and 70%.
|
|
|
| |
 |
Mammography BR3D Phantom
|
|
The Mammography BR3D Phantom is designed to assess detectability of various size lesions within a tissue equivalent, complex, heterogeneous background. This phantom provides more realistic challenges for standard screen and FFDM mammography systems as well as Tomosynthesis and breast Computed Tomography.
|
|
|
| |
|