SPECIFICATIONS

ASM-990 Series Advanced Survey Meter

Operating modes Rate, Integrate, Scaler (dual option): “Based On Measurement” or “Based On Time”,
Timed Peak Hold, Data Logging
Accuracy Within 10% of reading between 10% to 100% of full scale; indication on any range, exclusive of typical energy dependence. Accuracy is probe dependent
Detector Accepts GM detectors and scintillation probes operating at high voltages between 500 and 1300 volts
Temperature range 14° to 122°F (- 10° to + 50°C)
Relative humidity 0 to 95%, non-condensing
Warm up time 5 second diagnostic check
Check source Natural uranium, mounted on the case
Power requirements Two “D” cells, 150 hours operation, automatically indicates when battery is low
Housing material Proprietary polycarbonate, splash-proof case
Display Liquid crystal display, 2.2 x 2.2 in (5.6 x 5.6 cm)
Data logging modes The ASM-990 series Log Data feature can easily be accessed via the Setup Sub-menu. The unit can log/save a maximum of 500 data points in any of three separate modes (Manual and Survey modes can utilize the optional barcode scanner)


  • Manual Individual rate data points can be saved by pressing the Start/Stop/Rst  /Save button
  • Timed A data point will automatically be saved at user selectable time intervals in the range of 1 to 255 seconds
  • Survey Programmed sequences can be accessed via the menu system. Pressing the Start/Stop/Rst /Save button saves the current reading and displays the next survey location. Programming of  survey sequences, as well as retrieval of logged  data, is accomplished via the built-in IrDA port.
 

Label names up to 20 characters can be programmed into the unit to identify the individual survey locations

Weight (without probe) ASM 990, 992 2.1 lb (0.95 kg), ASM 993 2.4 lb (1.09 kg)
Dimensions 4.125 (w) x 10.91 (d) x 2.5 in (h) (10.47 x 27.71 x 6.35 cm)
Probe connector The unit is available with a MHV connector The unit can be used with multiple probes (5 total) by selecting the appropriate probe from the main menu. All calibration data for each probe is stored in the unit’s EEPROM

Specifications for ASM-992 and ASM-993 internal energy compensated 1 R/hr GM detector

Range 0.1 mR/hr to 1 R/hr
Radiation detected Gamma above 60 keV
Accuracy ± 10% of reading between 10% and 100% of full scale on any range, exclusive of energy dependence

Specifications for ASM-993 internal pancake detector
Radiation detected Alpha above 3.5 MeV, beta above 35 keV and gamma above 6 keV
Range Background to 80 mR/hr
Window 15 cm2 (1.75 in Ø) mica, 1.4 to 2.0 mg/cm2
Typical background 30 CPM Protective screen Stainless steel, hexagonal pattern providing 86% open area
Accuracy ± 10% of reading between 10% and 100% of full scale on any range, exclusive of energy dependence (protective cover open)

Note The ASM-990 series, with the customer selected probe is calibrated to NIST standards. The ASM-990 series with GM probe standard calibration is in R, Sv, and rems. Scintillation detectors are calibrated in counts. Radionuclide specific efficiency calibrations are available upon request.