Indicated Use Area monitoring
Detectors 2"x2" Nal(Tl) Scintillator
Display 4 digit LED display with 0.8" (2 cm) digits
Display Units Can be made to display in µR/hr, mR/hr, R/hr,µSv/h, mSv/h, Sv/h, hr, cpm, cps
Linearity Reading within ±10% of true value with detector connected
Response Typically 3 seconds from 10% - 90% of final reading
Status (Green light) instrument functioning properly
Low Alarm Indicated by yellow LOW ALARM light and slow beep (1 per second) audible tone ( can be set at any point from 0.0 - 9999)
High Alarm Indicated by red HIGH ALARM light and fast beep (4 per second) audible tone (can be set at any point from 0.0 - 9999)
NOTE: Audible alert and alarm indicators can be configured as a single beep if desired
Low Bat (yellow) indicates less that 2 hours of battery power remaining
Dead Time Adjustable to compensate for dead time of detector and electronics
Overload Senses detector saturation (indicated by display reading "-OL-")
Overrange Indicates radiation field being measured has exceeded counting range of instrument (indicated by display reading "----")
|
|
Data Output 9 pin connector providing 5 decade logarithmic output, RS-232 output, 10BaseT Ethernet output, signal ground connection, FAIL and ALARM signals (current sink), and direct connection to battery and ground
Remote (optional): Model 271, or 272 Remote units
Calibration Control Accessible from front of instrument (protective cover provided)
Power 95 - 135 VAC (178 -240 VAC available ), 50-60 Hz single phase (less than 100mA),
6 volt sealed lead-acid rechargeable battery (built in)
Battery Life Typically 8 hours in non-alarm condition; 12 hours in alarm condition
Battery Charger Battery is continuously trickle charged when instrument is connected to line power and turned on
Construction Aluminum housing with ivory powder coat paint
Temperature Range 5° F(-15° C) to 122° F(50° C)
May be certified for operation from -40° F(-40° C) to 150° F(65° C)
Size 10.3"(43.2cm)H X 9.7" (24.6cm)W X 3.3"(8.4cm)D
Weight 9.3 lbs(4.2 kg)
|