JRT Associates   Nuclear Medicine
Radiation Oncology
Emergency Preparedness
PET Imaging
Nuclear Cardiology
Medical Physics
Home Products Contest Central Newsletters JRT Calibrations Contact JRT
SPECIFICATIONS

1060AM Digital Smart Area Monitor

Radiation Detected Gamma rays
Typical Energy Dependence ± 15% from 100 keV to 1.5 MeV
Operating Range: Environmental
1 μR/hr to 1000 μR/hr (0.01 μSv/hr to 10 μSv/hr)
Operating Range: Low 0.01 mR/hr to 1 R/hr (0.1 μSv/hr to 10 mSv/hr)
Operating Range: Medium 0.1 mR/hr to 10 R/hr (1 μSv/hr to 100 mSv/hr)
Operating Range: High 1 mR/hr to 100 R/hr (10 μSv/hr to 1 Sv/hr)
High Voltage Regulated 500 to 2500 VDC, < 1 mV ripple, digitally controlled with 1 V resolution, 500 microamperes at 1400 V
Input Circuitry High and low discriminator setpoints. Jam detection (anti-jam)
 

Power Requirements 12 VDC @ 500 mA power converter
Enclosures A plastic rectangular housing, NEMA 4 type for outdoor or indoor applications
User Interface RS-485 supporting multi-drop applications for communications with IBM® compatible personal computer running WIN1060 applications software
Temperature Range 32° to 122°F (0° to 50°C)
Relative Humidity 5 to 95%, non-condensing
Shock and Vibration Mechanical shock and vibration specifications are per ANSI N42.17A, Section 8.4 and 8.5
Operating System Real-time, interrupt driven, embedded system