RADIOLOGICAL
Sensitive to X and y radiation, ß particles
Direct readout of dose equivalents
Hp (10) (deep/whole body) and
Hp (0.07) (shallow/skin)
Display Units Sv and rem (with
prefixes), OR scaled in Sv and cGy
(with prefixes)
Neutron Response <2%
Dose Display and Storage 0 μSv to >16 Sv (0 mrem to >1600 rem)
auto ranging
Resolution for Display 1 μSv (0.1
mrem), up to 10 mSv (1 rem)
Resolution for Storage 1/64 μSv
(=1.5 μrem)
Dose Rate Display 0 μSv/h to >4 Sv/h (0 mrem/h to >400 rem/h)
auto ranging
Alarms dual Hp (10) dose and
dose rate alarms; Hp (0.07) dose
and dose rate alarms
Energy Response Photon, Hp(10) ±50% 15 keV to 17 keV (ref. 137Cs); ±20% 17 keV to 1.5 MeV
(ref. 137Cs); ±30% 1.5 MeV to 6 MeV (ref. 137Cs);
±50% 6 MeV to 10 MeV (ref. 137Cs).
Photon,Hp(0.07) ±30% 20 keV to 6 MeV (ref.137Cs);
±50% 6 MeV to 10 MeV (ref. 137Cs);
Beta, Hp(0.07)±30% 250 keV to 1.5 MeV E
(ref.90Sr/90Y)
Angular Response Hp(10) 137Cs ±20% up to ±75°;
Hp(10) 241Am ±50% up to ±75°;
Hp(0.07) 90Sr/90Y ±30% up to ±55°
Accuracy Hp(10) 137Cs±10% Hp(0.07) 90Sr/90Y ±20%
Dose Rate Linearity Hp(10) 137Cs ±10% <0.5 Sv/h (<50 rem/h);
±20% 0.5 Sv/h to 1Sv/h(50 to 100 rem/h); ±30% 1 Sv/h to 2 Sv/h(100 to 200 rem/h);
±50% 2 Sv/h to 4 Sv/h(200 to 400 rem/h)
Between 4 Sv/h and 50 Sv/h
continues to accumulate dose at a
rate > 4Sv/h
Hp(0.07) 90Sr/90Y±20% <1Sv/h (<100 rem/h)
Between 1Sv/h and 50 Sv/h
continues to accumulate dose at a
rate > 1Sv/h
MEMORY
- 10 year data retention without
battery
- Short term dose registers for
Hp(10) and Hp(0.07)
- Approved Dosimetry Service
(Dose of Record) dose memory
area with password protection
- Peak dose rates with time of
occurrence
- All stored times have 1 second
resolution
- Count down timer, 1 hour 39
minutes 59 seconds maximum,
resolution 1 second
- Event log, 23 entries for time
recording of alarms, etc., for
incident assessments
- Dose profile history: settable
interval from 2 seconds to 35
hours, stores transitions of Hp(10)
and Hp(0.07) at a resolution of
1 μSv (0.1 mrem); will store up to
579 records for transitions up to
127 μSv or less
|
|
ALARMS
- Audible and visual alarms for dose,
dose rate, count down time, read
time and failure modes.
- Hp(10) dose chirp settable from
0.01 μSv/chirp to 100 μSv/chirp
(1 μrem to 10 mrem/chirp)
ELECTRICAL AND MECHANICALPower Supply single AA battery
1.5 V alkaline cell for typically 8
weeks continuous operation, OR
3.6 V lithium for typically 5 months
continuous operation
(interchangeable)
Alarm Sounder Fully sealed
typically 97dB(A) at 20 cm with
multiple modes
Communications IR interface up
to 1 meter range (39")
Display and Function Control Single button on front (recessed to
prevent inadvertent operation)
Size 85 x 63 x 19 mm (3.3" x 2.5"
x 0.8") excluding clip
Weight 95 g (3.2 oz) including
battery and clip
Case Material High impact
polycarbonate/ABS blend
ENVIRONMENTAL
Operating Temperature -10 °C to +40 °C
(+15 °F to +105 °F)
Humidity 20% to 90% RH
non-condensing
Vibration IEC 1283: 2g, 15min.,
10 to 33 Hz
Shock 1.5 m (5’) drop on each
surface onto concrete
EMI/EMC Exceeds MIL STD
461D RS103
|