JRT Associates   Nuclear Medicine
Radiation Oncology
Emergency Preparedness
PET Imaging
Nuclear Cardiology
Medical Physics
Home Products Contest Central Newsletters JRT Calibrations Contact JRT
SPECIFICATIONS

DMC-2000GN Gamma/Neutron Personal Dosimeter

Physical Characteristics

  • Compliant to IEC61526 Ed2 for gamma and neutron
  • Display units : mSv or mrem

Neutron Measurement

  • Dose display: 1 μSv to 10 Sv (0.1 mrem to 1000 rem)
  • Measurement range: 10 μSv to 10 Sv (1 mrem to 1000 rem)
  • Dose rate display: 10 μSv/h to 10 Sv/h
  • Energy range: 0.025 eV to 15 MeV

Gamma Measurement

  • Dose display: 1 μSv to 10 Sv (0.1 mrem to 1000 rem)
  • Rate display: 0,1 μSv/h to 10 Sv/h (0.01 mrem/h to 1000 rem/h )
  • Energy range: 50 keV to 6 MeV
  • Linearity: <± 10% up to 1 Sv/h (100 rem/h ); <± 25% up to 10 Sv/h (1000 rem/h )

 

Electrical Characteristics

  • Standard calculator battery LiMnO2 CR2450
  • 6 months battery life on continuous use

Physical

  • Dimensions (l x w x h): 3.4 x 1.9 x 0.85 in (87 x 48 x 21 mm) without clip
  • Weight: 2.8 oz. (80 g) with battery

Environmental Characteristics

  • Temperature range: 14°F to 122°F (-10°C to 50°C)
  • Humidity: < 90% at 108°F (42°C)
  • Storage: -22°F to 160°F (-30°C to 71°C)
  • Shock, vibration and drop resistant
  • Waterproof