Radiation detected Gamma rays
Typical energy dependence ± 15% from 100 keV to 1.5 MeV
Operating Ranges
Environmental Range 1 μR/hr to
1000 μR/hr
(0.01 μSv/hr to 10
μSv/hr)
Low Range 0.01 mR/hr to 1 R/hr
(0.1 μSv/hr to 10 mSv/hr)
Medium Range 0.1 mR/hr to 10
R/hr (1 μSv/hr to 100 mSv/hr)
High Range 1 mR/hr to 100 R/hr
(10 μSv/hr to 1 Sv/hr)
High Voltage Regulated 500 to 2500 VDC, < 1 mV ripple, digitally
controlled with 1 V resolution, 500 microamperes at 1400 V
Input Circuitry High and low discriminator setpoints. Jam detection
(anti-jam)
Power Requirements 12 VDC @ 500 mA
Enclosures A plastic rectangular housing, NEMA 4 type for outdoor or indoor applications.
Outside Dimensions 3.8 x 11.125
x 4.0 in
(9.65 x 28.26 x 10.16
cm)
Mounting hole pattern 2.9375 x
9.375 in
(7.46 x 23.81 cm)
User Interface RS-485 supporting multi-drop applications for
communications with IBM® compatible personal computer running
WIN1060 applications software
ENVIRONMENTAL
Temperature Range 32° to 122°F (0° to 50°C)
Operating Limits - 52° to 230°F (- 47° to 110°C)
Relative Humidity 5 to 95%, non-condensing
Shock and Vibration Mechanical shock and vibration, 15 Grms,
10 to 2,000 Hz
Operating system: Real-time, interrupt driven, embedded system
SPECIFICATIONS FOR MODEL 1060DA
Range 5 decades, based on 1060AM-V
|
|
OPERATOR INTERFACE
Radiation Values Display Digital, microprocessor controlled,
intelligent display
Type PLED, 16 x 2 matrix, 2 lines,
16 characters per line
Line 1 Displays radiation value
and engineering units
Line 2 Displays alarm messages
(HIGH ALARM,
OVERRANGE, JAM,
FAIL)
Luminance 350 cd/m2, min
Display Size 2.56 (w) x 0.63 in (h)
Character Size 0.20 in, typical
(0.105 x 0.197 in)
Color Yellow/Green
Value Up to five digits with
floating decimal point
Units Auto ranging, mR/hr; SI
HIGH ALARM INDICATORS
Visual Red, High intensity LED;
0.78 in Ø;
Default setpoint is 2.0 mR/hr
Audible 103 ± 5 db(A) siren at 15 VDC, 24 inches, 25°C;
2,900 ± 250 Hz operating frequency;
Stainless steel diaphragm
Alarm Silence Single pole, push to make, momentary push button
switch silences Audible alarm. Also initiates a self-test routine when
held for three (3) seconds
ENCLOSURE
Ingress Protection IP65 DIN VDE 0470/EN 60529, up to NEMA 4
Enclosure dimensions: 7.5 (l) x 2.24 in (w) x 1.26 in (h) (approx.)
Overall: 8.9 in (l) x 3.42 in (w) x 1.88 in (h)
Weight 0.85 lbs (Approximate)
Mounting 4, adjustable foot mounting brackets provided
EXTERNAL CONNECTIONS
I/O Cable 6 conductor, 22 AWG, shielded cable interconnects digital
display and alarm unit to 1060AM-V controller (Model 50-113)
Mating Connector Switchraft EN3 Mini Weathertight connector
supplied with unit (Model 32-122)
Max Length 50 feet
Size Approx. 0.23 in OD
|